JS/JT Series Thyristor Regulators
CHINO Japanese Page
Home Products Corporate Infomation Downloads Request Catalog

Thyristor Regulators
Thyristor Regulators

JS/JT Series Thyristor Regulators

 

 

The JS/JT series is small and lightweight thyristor regulators with built-in firing unit for high density of mounting on instrumentation panels.

Features
  • Wide selection from 10A to 1000A on both single-phase and three-phase load applications
  • Two control systems of phase-angle firing system and zero-cross firing system
  • 4 kinds of feedback type of voltage feedback, current feedback, power feedback and without feedback are available in accordance with the characteristics of heating element on the phase-angle firing system
  • Two kinds of zero-cross firing system, conventional type and deltasigma modulation type, are available for sensitive power control
  • Protection functions including thyristor gate-off and rapid fuse are built-in.

Models
Control systems/Feedback systems Single-phase 3-phase
Power voltage
100V
Power voltage
200V
Power voltage
400V
Power voltage
100V
Power voltage
200V
Power voltage
400V
Phase-angle firing/Voltage feedback JS-1squaresquaresquareVsquare JS-2squaresquaresquareVsquare JS-4squaresquaresquareVsquare JT-1squaresquaresquareVsquare JT-2squaresquaresquareVsquare JS-4squaresquaresquareVsquare
Phase-angle firing/Current feedback JS-1squaresquaresquareAsquare JS-2squaresquaresquareAsquare JS-4squaresquaresquareAsquare JT-1squaresquaresquareAsquare JT-2squaresquaresquareAsquare JS-4squaresquaresquareAsquare
Phase-angle firing/Power feedback JS-1squaresquaresquareWsquare JS-2squaresquaresquareWsquare JS-4squaresquaresquareWsquare JT-1squaresquaresquareWsquare JT-2squaresquaresquareWsquare JS-4squaresquaresquareWsquare
Phase-angle firing/Without feedback JS-1squaresquaresquareNsquare JS-2squaresquaresquareNsquare JS-4squaresquaresquareNsquare JT-1squaresquaresquareNsquare JT-2squaresquaresquareNsquare JS-4squaresquaresquareNsquare
Zero-cross firing/Conventional type       JT-1squaresquaresquareZsquare JT-2squaresquaresquareZsquare JS-4squaresquaresquareZsquare
Zero-cross firing/deltasigmamodulation type JS-1squaresquaresquareCsquare JS-2squaresquaresquareCsquare JS-4squaresquaresquareCsquare      
Rated current: The abovesquaresquaresquarespecifies the rated current. (ex. 010 for 10A)
10A: 010, 20A: 020, 30A: 030, 50A: 050, 75A: 075, 100A: 100, 150A: 150, 200A: 200,250A: 250, 300A: 300, 400A: 400, 500A: 500, 750A: 750, 1000A: X00

Specifications
Rated voltage 100V/110V/120V, 200V/220V/240V, 380V/400V/440V AC (to be specified)
Frequency 50/60Hz (selected by terminal)
Rated current 14 kinds of 10A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 250A, 300A, 400A, 500A, 750A, and 1000A (Reference: Ambient temperature of 50°C)
Input signal 3 kinds of 4 to 20mADC, 1 to 5mADC, and ON-OFF contact signal (selected by terminal)
Input resistance 4 to 20mADC: less than 100ohm, 1 to 5mADC: less than 400ohm
Output range Phase-angle firing system
Voltage feedback type: 0 to 98% (95%) of rated voltage
Current feedback type: 0 to 100% of rated current
Maximum voltage output: 98% (95%) of rated voltage
Power feedback type: 0 to 98% (95%) of rated voltage x 0 to 100% of rated current
Without feedback: 0 to 98% (95%) of rated voltage
Zero-cross firing system
Conventional type: 0 to 100% of rated voltage, Frequency division cycle: 1.5 second
deltasigma modulation type: 0 to 100% of rated voltage
The figures in ( ) indicate the output for 3-phase control.
Load applicable Resistive load and inductive load (Primary side control of transformer)
Resistive load only for frequency division control system
Allowable voltage fluctuation 85 to 110% of rated voltage
Operating temperature range Performance guarantee range: 0 to 50°C
Operation guarantee range: -50 to 50°C
Cooling system Self-cooling (Rated current: Single-phase - less than 150A. 3-phase - less than 75A)
By built-in cooling fan (Rated current: Single-phase - more than 200A. 3-phase - more than 100A)
Over current protection Thyristor gate off
Over current protection function is not available for phase control system without feedback, but the current transformer (CT) for detecting current is sold separately.
Alarm Over current alarm (on mounting CT for detecting current), Rapid fuse melting (more than 30A)
Cooling fan abnormal (Single-phase: more than 200A, 3-phase: more than 1150A): Contact output, lamp indication
Load disconnection alarm (deltasigma modulation type only): Lamp indication
Accessories Variable resistor (10kohm)for gradient setting or low limit setting
Variable resistor (2kohm)for manual setting, high limit setting or for elevation
Variable resistor (10kohm, 2kohm)for high limit setting and low limit setting
Variable resistor (10kohm, 2kohm)for output indicator, gradient setting/manual setting and selection switch

Page Top

BACK

 


Copyright(c) CHINO corporation 1999-2004 All Rights Reserved.