Recorders / Loggers
Graphic
Recorders |
 |
 |
|
 |
|

|
BR Series
Graphic Recorders
|
|
|
|
| The BR series
graphic recorders fit various applications in industrial
fields to test/research fields. The measured data are
displayed on a 5.5" TFT color LCD display, stored
into the internal flash memory and can be saved to a 3.5"
floppy disk. You can
convert electronic data to a popular spreadsheet software
by using the optional software [PASS]. The MODBUS communications
link to computer systems makes the configuration with
your personal computer easy. The recorders need no consumable
costs including chart papers and inks used in conventional
recorders. |
 |
|
Features
- Wide range of display
functions
Points can be classified into maximum
5 groups and a trend screen, a data screen, a bargraph
screen or a multi-screen can be displayed for each
group. A historical trend screen, a real-time/historical
trend screen (dual trend) or an alarm summary screen
can be displayed, too. A functional jog dial allows
quick selection of screens.
- Storage of measured
data
The measured data (maximum 654,000
data) are stored in the 1.2MB (3MB:option) internal
memory by 6 kinds of storage mode. The measured data
can be copied from the internal memory to a 3.5"
floppy disk. Total 200 of message event and alarm
event can be stored.
- Easy processing of measured
data
Various kinds of screen make management
and processing of the measured data easy. The historical
data, which have been stored in the internal memory
or saved in the floppy disk, can be displayed and
compared. A search function of the specified data
is provided.
- Safety standards
The recorders comply with CE and
have UL/CSA approval. The door and bezel are protected.
(IP54) (Note: Some models are pending UL/CSA approval.)
- Easy settings
The interactive system on the window
opened by selecting items from the menu screen allows
easy programming. Using the engineering port, you
can easily set up the parameters by using the parameter
programming software [PASS] through a personal computer,
too.
- Data management by message
function
Messages (maximum 30 alphanumeric
characters) can be written on the trend screen. Up
to 10 kinds of message can be pre-registered and written
by the keyboard, communications, or remote contacts.
The message can be written on the historical trend
screen, too.
- Communications
2 ports (a master port and a slave
port) for communications are available as an option.
The slave port is for RS-232C, RS-422A or RS-485 with
MODBUS protocol. The MODBUS communications link makes
the system configuration with your personal computer.
Ethernet local area network is available, too.
The master port is for the connection of CHINO's hybrid
recorders (AL3000/AH3000), field scanner (SE3000)
and digital controllers (up to 30 input points).
- Software package
The data acquisition software package
(KIDS) and the parameter programming software package
(PASS) are optionally prepared for easy data management
by your personal computer. Also the parameter programming
software package (pocketPASS) for palm sized computers
is optionally available.
|
|
Models
| Types |
Input
points |
Measuring
cycles |
Models |
| Standard
input type |
6-point |
5
seconds/6-point |
BR1761-N00 |
| 1
second/6-point |
BR17A2-N00 |
Continuous
input type
|
1-point |
0.1
second |
BR1713-N00 |
| 2-point |
BR1723-N00 |
| 3-point |
BR1733-N00 |
| 4-point |
BR1743-N00 |
Communications
interface for RS-232C, Rs-422A or RS-485: Option
Alarm output: Option
Specifications
| Measuring
points |
Standard
input type |
6,
12 points |
| Continuous
input type |
1, 2,
3 or 4 points |
| Input
signals |
Universal input (DC voltage 10 kinds, Thermocouple
35 kinds, Resistance thermometer 11 kinds,
DC current (by shunt resistors) |
| Range
setup |
Programming
of input types and ranges by the keyboard. The measuring
range is automatically selected by the range programmed.
|
| Scale
setup |
Programming
of maximum values, minimum values and engineering
units from the keyboard. |
| Accuracy
rating |
±0.1%
± 1 digit (DC voltage input) |
| Measuring
cycles |
Standard input type |
About
1 second/6-point, 2 seconds/12-point or about 5
seconds/6-point |
| Continuous
input type |
About
0.1 second/1-point, 2-point, 3-point or 4-point |
| Reference
junction compensation accuracy |
K,
E, J, T, N, Platinel II |
Maximum
± 0.5°C |
|
R, S, NiMo-Ni, CR-AuFe, WRe5-WRe26, W-WRe26, U,
L |
Maximum ± 1.0°C |
| (The
above errors are added to the accuracy ratings for
the internal reference junction compensation.) |
| Burnout |
Detection
of signal disconnection for thermocouple inputs
and resistance thermometer inputs
Up-scale burnout, down-scale burnout or burnout
disabled is selectable for each input. |
| Input
resistance |
Thermocouple
inputs |
About
8M
|
| DC
voltage inputs |
Less
than ±2V: about 8M ,
±5V to ±50V: about 1M |
| Allowable
signal source resistance |
Thermocouple
inputs (burnout disabled)
DC voltage inputs(maximum
± 2V) |
Maximum 1k
|
| DC
voltage inputs(±
5V to ± 50V) |
Maximum
100 |
Resistance
thermometer inputs
[Pt100 (IEC751-1995), Pt100 (IEC751-1983), JPt100,
Pt50, Pt-Co] |
Maximum 10
per wire
3 wires - same
resistance |
| Input
correction |
Zero, span and shift adjustments for each channel |
|
Display
|
5.5"h TFT color LCD (320 x 240 dots:111.36mmx
83.52mm) |
| Trend
display colors |
10
colors (selectable) |
| Operation
screens |
Screens
are switched by scroll key and entry key. Maximum
5 groups except alarm summary screen can be switched
and displayed. (Maximum 6 channels/group) |
| Trend
screens (with scale plate and pointer displays)
|
Selects
from real-time trend, historical trend and dual
trend screens
Vertical or horizontal
time scale orientation selectable
Data display enabled or disabled selectable
Scrolling available
Zone recording, compressed/ expanded recording |
| Bargraph
screen |
Data
display enabled or disabled selectable |
| Data
screen (Data + Tag + Engineering unit + Alarm activation
status) |
|
Multi-screen |
Real-time
trend screen + Bargraph screen + Data screen |
|
Alarm summary screen |
Current
alarm output status and alarm log (channel, level,
alarm event time) |
| Skip
function (Trend and Data screens) |
The
channels to be skipped in display can be programmed
for each group. |
| Replay
(Historical trend) |
Historical
data is displayed by specifying a file.Data
logging is continued.
* Replay by scrolling or by time specified
* Enable to replay from a floppy disk |
| Scroll
function |
Referring to historical data by the cursor is enabled
on the trend screens. |
| Data
search function (Historical trend) |
The
trend display position matching the following conditions
is searched automatically from the data in the replay
file and the cursor is moved to the position.
- Channel A data
= Channel B data
- Channel A data
< Channel B data
- Channel A data
< Data specified (optional programming)
- Data of Channel
A > Data specified (optional programming)
- Data 1 specified
(optional programming)
Data of Channel
A
Data 2 specified
(optional programming)
|
| Message
display |
Displays messages on the trend screen through the
keyboard or by remote contacts signal and stores
them as a message dada file (maximum 200 messages).
Enables to display and stores them on the historical
trend screen.
* Messages can
be pre-stored. (maximum 10 messages, maximum 30
characters/message) |
| Display
updating intervals |
Trend
screen
|
Depended
on time scale programmed, minimum 1 second |
| Data
Screen |
Continuous
input type: about 1 second, Standard input type:
about 5 seconds |
|
Time scale programming |
0.1, 0.2, 0.5 second (continuous input type only)
1, 2, 3 seconds (continuous input type and about
1 second/6-point specification of standard input
type)
5, 10, 15, 20, 30 seconds (all models)
1, 2, 3, 5, 10, 15, 20, 30, 60 minutes (all models) |
| LCD
saver |
When
no key is operated for the specified period of time
(programmable period: 1 to 60 minutes), the back-light
is dimmed and the screen saver display appears. |
|
Internal
memory
|
3MB |
|
Storing interval |
0.1,
0.2, 0.5 second (continuous input type only)
1, 2, 3 seconds (continuous input type and about
1 second/6-point specification of standard input
type)
5, 10, 15, 20, 30 seconds (all models)
1, 2, 3, 5, 10, 15, 20, 30, 60 minutes (all models)
|
| Storing
data |
Measured data (Maximum 5 files on simultaneous storage),
Message (1 file), Alarm event (1 file), Programmed
parameters (1 file)
- Measured data
- File number, storage start date/time, Storage
interval, Scale data, Measured data
- Message - Time,
Message text
(Max. 200 messages)
- Alarm event -
Alarm event time, Channel, Level, Alarm type
(Maximum 200 information)
- Programmed parameters
- Storage date/time, all parameters (Updated
at reprogramming)
|
| Measured
data stored |
2-bite
binary/1 data
* Stores both
minimum values and maximum values in case that the
storing interval is longer than the measuring interval.
(For the standard input
type programmed with the storing interval other
than 5 seconds and for the continuous input type
programmed with the storing interval other than
0.1 second. ) |
| Storage
into internal memory |
The
following conditions are selectable on the keyboard.
Manual operation (keyboard)
Trigger signal (Remote contacts, Alarm activation)
Storage during conductive signal ON (Remote
contacts)
Start/end by time (End on the keyboard is enabled.)
A file is closed when it has been fully written.
|
| Status
output |
When
90% of the storage space in a file has been written,
the status can be output at alarm output terminals.
|
| Memory
usage display |
The amount (%) of memory used in each file is displayed
on the operation screens. |
| External
memory medium |
3.5"
floppy disk (2HD:
1.44MB MS-DOS formatted)
Data in internal memory
can be copied to a floppy disk through the keyboard.
|
| Storing |
Copys
data in the internal memory to a floppy disk or
a memory card. |
| Alarm
types |
High alarm, low alarm, differential high alarm,
differential low alarm, rate-of-change increase
alarm, rate-of-change decrease alarm |
| Alarm
programming |
Individual
programming for each channel, Maximum 4 levels/channel
|
| Alarm
storage |
Storage of alarm event time and alarm types |
| Alarm
output (option) |
6-point
(AND/OR output enabled) (option) |
| Rated
power voltage |
100 to 240VAC, 50/60Hz |
| Power
consumption |
Maximum
45VA |
| Power
failure protection |
Programmed
parameters stored into EEPROM memory, Data stored
into flash memory, Clock circuit and data sustained
for minimum 6 years by a lithium battery (at the
operation more than 8 hours/day) |
| Environmental
conditions |
- Reference operating
condition
|
| Ambient
temperature/humidity range |
21 to 25°C, 45 to 65%RH, |
|
Power voltage |
100VAC
± 1% |
| Power
frequency |
50/60Hz
± 0.5% |
| Attitude |
Left/right
0 degree, Forward tilting 0 degree, Backward tilting
0 degree |
| Warm-up
time |
More
than 30 minutes |
- Normal operating
condition
|
| Ambient
temperature/humidity range |
0
to 50°C, 20 to 80%RH
On using a floppy disk: 5 to 40°C |
| Power
voltage |
90
to 264VAC |
| Power
frequency |
50/60Hz
± 2% |
| Attitude |
Left/right
0 degree, Forward tilting 0
degree, Backward
tilting 0 to 20 degrees |
| Weight
|
About
3.2kg |
- International safety
standards
| CE |
EN61326
+ A1 Class A, EN61000-3-2 + A14
EN61000-3-3, EN61010-1 + A2 |
| UL |
UL3111-1(Some
models are pending approval.) |
| CSA
(C-UL) |
C22.2
No. 1010 (Some models are pending approval.) |
| IP |
IEC IP54
(front protection) |
Options
|
Options
|
Specifications
|
|
Remote
contacts/alarm output
|
Remote
contacts
|
The following operation is available by contact
input (4 points) and common (2 points) signals.
(parameter connection)
Data memory operation
Message display
Totalizing reset
|
|
Alarn
output
|
Independent
output at alarm activation: 6 points
| Contact
rating |
MOS relay output |
240VAC/DC 50mA
resistive output |
Mechanical
relay output
(Form A and Form B) |
100VAC, 0.5A
resistive load |
| 240VAC, 0.2A
resistive load |
| 100VDC, 0.3A
resistive load |
| *
Form C mechanical relay: Not complying with
CE, UL and CSA (C-UL) |
|
|
Communications
|
Ethernet,
RS-232C, RS-422A or RS-485 (MODBUS protocol) (to
be specified)
For RS-422A or RS-485. A line converter (CHINO's
SC-8 - sold separately) is necessary between BR
and a personal computer.) |
|
2-port
communications
|
In
addition to the slave port for communication with
a personal computer, the mater port is prepared
to acquire data from CHINO's instruments..
Interface: RS-422A or Rs-485 (to be specified)
Protocol: MODBUS
Applicable instruments:
Recorders - BR, AL3000, AH3000, SE3000
Controllers - LT series, DZ1000, DZ2000 |
|
Mathematics
|
Arithmetic,
Square root, Logarithm, Natural logarithm, Exponential,
Maximum, Minimum, Average, Temperature/humidity
|
|
Totalizer
|
Totalizing
measured data or calculated data
| (1) |
Interval: 1
minute to 24 hours or no interval |
| (2) |
Start time:
0 hour 0 minute to 23 hours 59 minutes |
|
|
Daily
report file
|
Creates
a daily report file by specifying channels, time
(optional time, max. 24 points) and the following
items.
(1)Instant value, (2) Maximum value in block,
(3) Minimum value in block, (4) Average value
in block, (5) Maximum value in day, (6) Minimum
value in day, (7) Average value in day
|
Page Top BACK
|
|
|
|