IR-M2000 Series Fiber Optic Infrared Moisture Meters
CHINO Japanese Page
Home Products Corporate Infomation Downloads Request Catalog

Infrared Moisture Meters/ Infrared Thickness Meters
Infrared Moisture Meters

IR-M2000 Series Fiber Optic Infrared Moisture Meters

 

 

The IR-M2000 Series is fiber optic on-line moisture meters utilizing the infrared absorption of moisture. The sensing part is a fiber optics and can be installed at narrow space and high temperature environment.

Converting capabilities are built into the compact designed detector unit for easy installation and operation. Maximum 99 calibration curves can be stored into memory for many applications. The unit can be used by itself or by combining with personal computers as an analog output and a communication function are provided with.

A setting display unit connectable with maximum 9 detector units can set various kinds of setting items of the detector unit and displays moisture value.

 

Features

  • High sensitive fiber optics
    The measurement is stable by high sensitive fiber optics. A reflection type fiber optics with lens can measure objects at long measuring distance.
  • Compact sensor part
    The compact and lightweight sensing part using the fiber optics can be used at narrow spaces and places where the direct sighting is difficult.
  • For location in environment at 150°C
    Any water-cooling in the environment at 150°C is not required by the heat-sensitive fiber optics.
  • Setting display unit
    The setting display unit has a front panel of 96 x 96 mm and can connect with up to 9 sets of the detector unit. The communications interface between the setting display unit and the detector unit is by RS-485.
  • Protective structure conforming to IP-65
    The enclosure of the detector unit and the front panel of the setting display unit conform to IP-65 for severe atmospheric condition.

Models

  • Detector unit

Measuring objects

Communications interfaces

Applicable fiber optics

Universal types

High moisture types

IR-M2100S

IR-M2200S

RS-485 (standard)

Reflection type

IR-M2100R

IR-M2200R

RS-232C

IR-M2100A

IR-M2200A

RS-422A

IR-M2150S

IR-M2250S

RS-485 (standard)

Transparent type

IR-M2150R

IR-M2250R

RS-232C

IR-M2150A

IR-M2250A

RS-422A

  • Fiber optics

Models

Types

IR-WCRN
Reflection type
IR-WCRE
Reflection type with lens
IR-WCT
Transparent type*

* For liquid, a measuring cell for liquid is separately necessary.

  • Setting display unit

Models

Communications interfaces

IR-GMEG1S

RS-485

IR-GMEG1R

RS-232C

IR-GMEG1A

RS-422A

Specifications

  • Detector unit
Measuring system Infrared reflection type 3-wavelength system
Moisture output 4 to 20mADC (Load resistance: less than 500)
Correction input

4 to 20mADC (option)
(For correction of sample temperature, measuring distance, etc.)

Communications output RS-485, RS-232C or RS-422A (to be specified)
RS-485 for connection with the setting display unit
Output renewal cycle 28ms
Display LED 5-digit
Calibration curve number - LED 2-digit
Setting By keys or communications
Calibration curve Linear to cubic expression or broken line
Numbers of calibration curve 99 curves
Calibration curve correction Zero and span correction
Calibration curve creation Regression calculation
Calibration By a checking plate
Smoothing 0 to 99 seconds
Working temperature range 0 to 50 °C(Air is necessary for more than 45°C.)
Rated supply voltage 24VDC
Power consumption Maximum 36VA
Connection

Fiber optics - Connector connection
Power supply/signal line -Terminal connection

Casing Aluminum casing, drip-proof structure (conforming to IEC529 IP65)
Weight About 4kg
Accessory Power supply unit IR-WEP
  • Fiber optics
Measuring distance and measuring diameter Reflection type - phi20mm at 15mm, phi50mm at 50mm
Reflection type with lens - phi25mm at 25mm, phi40mm at 100mm
Fiber length

Reflection type, Reflection type with lens - 1.5m (up to 10m)
Transparent type - 2m (up to 20m)

Allowable bending radius

Reflection type, Reflection type with lens - R100mm
Transparent type - R250mm

Working temperature range 0 to 150°C
Fiber protection Stainless flexible tube
Purge air flow

Reflection type - 5 to 20Nl/min
Reflection type with lens - Without air purge function

  • Setting display unit
Detector unit input RS-485, connectable with up to 9 detector units
Analog output 4 to 20mADC (Load resistance: less than 500), 2 outputs
Output renewal cycle 28ms x (quantity of detector unit)
Display Data - LED 5-digit
Calibration curve number - LED 2-digit
Detector unit number - LED 1-digit
External setting

Setting of detector unit number, calibration curve number, calibration, preset output and hold by external contact

Alarm High/low alarms, Contact 2 outputs (H-C-L)
Working ambient temperature 0 to 50°C
Rated supply voltage 100 to 240VAC 50/60Hz
Power consumption Maximum 15VA
Casing ABS resin, Front panel - Drip-proof structure (conforming to IP-65)
Weight About 0.6kg
  • Power supply unit
Output voltage 24VDC
Output current 2.1A
Working ambient temperature 0 to 50°C
Supply voltage 100 to 120VAC, 200 to 240VAC, switching type, 47 to 450Hz
Power consumption Maximum 160VA
Weight About 380g
  • Package software Contents
Contents

 

Data logging, trend display, data storage and calibration curve creation
Up to 9 detector unit s are connectable.An electronic balance is connectable on the creation of calibration curve.
Environment IBM PC/AT compatible
OS Windows 95 Contact input board (option): IBX-2131 (ISA bus)