Controllers Indicators
Digital
Program Controllers
|
 |
 |
|
 |
|

|
DZ3000 Series
Digital Program Controllers
|
|
|
|
| The DZ3000 series
is 96mm x 96mm digital program controllers with PID auto-tuning
function and event output. Programs 8-step/2-pattern or
4-step/4-pattern can be stored into memory.Each 2 groups
of PID parameters and high/low output limiters can be
set and be automatically selected to fit to each programming
area. |
 |
Features
- Universal input of the
total of 19 inputs including 11 thermocouple inputs,
2 DC voltage inputs, 1 DC current input and 5 resistance
thermometer inputs
- Multi-control output
of on-off pulse type, current output type and SSR
drive pulse type
- Allowable power voltage
of 90VAC to 264VAC
- IP65 front panel
- Models complying with
CE are available. (for 24VDC power supply only)
|
|
Models
| Models |
| 8-step/2-pattern
|
4-step/4-pattern |
| DZ38U0-000 |
DZ34U0-000 |
Measuring ranges
|
Input
signals
|
Measuring
ranges
|
| Thermocouples |
R
|
0 to
1760°C
|
| S
|
0 to
1760°C
|
| B
|
0 to
1820°C
|
| K
|
-200
to 1370°C
|
| -200 to
500°C |
| E
|
-270
to 700°C
|
| J
|
-200
to 900°C
|
| T
|
-200
to 400°C
|
| N
|
0 to
1300°C
|
| U
|
-200
to 400°C
|
| L
|
-200
to 900°C
|
| DC
voltage |
-20
to 20mV, -5 to 5V
|
| DC
current |
0 to
20mA
|
| Resistance
thermometers |
Pt100
|
-200
to 660°C
|
| -200 to
200°C |
|
JPt100 |
-200
to 649°C,
|
| -200 to
200°C |
| Pt50
|
-200 to 649°C
|
Specifications
|
Input
signals
|
Thermocouples |
B,
R, S, K, E, J, T, U, L |
| DC
voltage |
±20mV,
±5V
|
| DC
current |
0 to
20mA
|
| Resistance
thermometers |
Pt100,
JPt100, Pt50
|
| Accuracy
rating |
±0.3%
of input span ± 1 digit |
| Measuring
unit |
°C
or °F (by internal switch)
|
| Sampling
period |
About 0.2 second |
| Burnout |
Upscale
burnout for thermocouple, mV and resistance thermometer
inputs |
| At
burnout |
Output
0% and high alarm activation |
| Measuring
input shift (sensor correction) |
-200
to 1000 times of setting resolution |
| Scaling |
DC
voltage and DC current inputs: Optional scaling
for range and scale (-1999 to 9999) |
| Scaling
decimal point |
0
to 3 |
| Display
resolution |
Temperature
input |
0.1°C (maximum measuring input: less than 1000°C) |
| DC
voltage/current input |
4-digit
display (Decimal point and scaling are optional.) |
| Power
supply |
100
to 240VAC, 50/60Hz (universal power supply) |
| Allowable
power supply |
90
to 264VAC |
| Ambient
temperature |
-10
to 50°C |
| Ambient
humidity |
20
to 80%RH (no dew condensation) |
| Power
interruption countermeasure |
Setting
parameters are retained more than 10 years. |
| Allowable
signal source resistance |
Thermocouple,
DC voltage: less than 100
Resistance thermometer: less than 5 /wire
(equal resistance for 3 wires) |
| Measuring
current (resistance thermometer input) |
2mA
± 20% |
| Power
consumption |
Maximum
15VA |
| Front |
IEC529
IP65 |
| Weight |
About
600g |
Program Specifications
| Program
setting system |
Pattern
setting by keys (target value/time system) |
| Program
composition |
Odd
step: Target value, requiring time
Even step: Requiring time |
| Step/pattern |
Maximum
8-step/2-pattern or maximum 4-step/4-pattern
16-step/1-pattern can be set. |
| Pattern
repetition |
Maximum
999 times |
| Setting
range |
Temperature:
Same as input range
DC voltage/current: Same as scale range
Time: 0 to 99 hours 59 minutes (1 minute-setting
resolution) |
| Start
temperature |
Input
value or optional setting value |
| Output
at end |
Constant
control of final setting value or 0% output, selectable |
| Area
parameter |
2
areas by dividing into upper part and lower part
at area shifting value |
| Step
parameter |
Setting
at each step
Event 1 valid/invalid
Event 2 valid/invalid
Exact temperature compensation valid/invalid (odd
steps only) |
Control Specifications
| Control
switching cycle |
About
0.2 second |
| Control
system |
Current
output type/On-off pulse type/SSR drive pulse type
PID
(2-position control output is selectable bi dip
switch.) |
| Control
setting accuracy rating |
±1
digit (relative error to indicating value) |
| Auto
tuning |
Provided,
PID constants can be also set manually. |
| PID
constants |
Two
groups switching by interlocking with SV (PID constants
corresponding to the aimed setpoint No. are used
during ramp operation of setpoints.)
P: 0.1 to 999.9%
I: 0 to 9999 seconds
D: 0 to 9999 seconds |
| ARW
(anti-reset windup) |
High:
0.0 to 100.0%
Lower: (-) 100.0 to 0.0% |
| Output
limiter |
Automatic
switching of two groups at area shifting value
High: 0.0 to 105.0%
Low: -5.0 to 100.0% |
| Output
variable limiter |
0.1
to 100.0% |
| Output
deadband |
0.1
to 9.9% (2-position control only) |
| Auto/manual
output |
Balanceless
bumpless |
| Manual
output range |
-5.0
to 105.0% (0.1% increment) |
| Control
action |
Direct
action/reverse action selectable (by dip switches) |
| Exact
temperature compensation |
1
to 9999 |
| Current
output type PID |
Output
signal |
4
to 20mADC |
| Load
resistance |
Less
than 600 |
| On-off
pulse type PID |
Output
signal |
On-off
pulse conductive signal |
| Contact
rating |
Resistive
load 100VAC 2A, 200VAC 1A, 24VDC 1A
Inductive load 100VAC 1A, 200VAC 0.5A, 24VDC 0.5A
Minimum load 5VDC more than 10mA |
| On-off
pulse period |
Variable
between about 1 to 120 seconds |
| Contact
protective element |
Not
built-in (sold separately) |
| SSR
drive pulse PID |
Output
signal |
On-Off
pulse voltage signal
ON: 12VDC ± 20% (maximum 20mA)
OFF: Less than 0.8VDC |
| On-off
pulse period |
Variable
between about 1 to 120 seconds |
Event Specifications
| Event
points |
2
points (EV1,EV2) |
| Event
system |
Absolute
value alarm: High/low limits, Standby function provided/not
provided Deviation alarm: High/low limits, Standby
function provided/not provided Output value alarm
- High/low, Standby function provided/not provided
Heater disconnection alarm (for pulse output type
controllers with optional CT input only) SV status
(ON during SV ramp, ON during SV no-ramp, Event
set values are ineffective in this case.) |
| Event
deadband |
0
to 9999 |
| Event
output |
Output
signal: Form A relay contact |
| Contact
rating |
Resistive
load 100VAC 2A, 200VAC 1A, 24VDC 1A
Inductive load 100VAC 1A, 200VAC 0.5A, 24VDC0.51A
Minimum load 5VDC more than 10mA |
| Contact
protective element |
Not
built-in (sold separately) |
Page Top