| Type |
Wall-mount
type |
Separated
type |
Separated
heat
resistive type |
Insertion
type
(soft type) |
Insertion
type
(hard type) |
| Model |
HN-CQ |
HN-CFA |
HN-CGA |
HN-CV |
HN-CP |
| Humidity |
Sensor |
High Polymer
capacitance type |
| Measuring
range |
0 to 100%RH
(no dew condensation) |
| Accuracy
rating |
±2%RH
(at 0 to 90%RH and 25°C), ±3%RH (at 90
to 95%RH and 25°C) |
| Relative
humidity/temperature coefficient |
±0.1%RH/°C
(at the range of 5 to 80°C) |
| Response
time |
Within
15 seconds (at 90% response, 25°C and under
0.1m/s wind flow) |
Within
1 minute (at the same condition shown left) |
| Output
signal |
4 to 20mADC,
2-wire transmission (against 0 to 100%RH) |
| Load
resistance |
500
or lower (at 24VDC power supply) |
| Temperature |
Sensor |
Platinum
resistance thermometer Pt100 JIS class A |
| Measuring
range |
0 to 50°C |
-40 to
80°C |
-40 to
180°C |
0 to 50°C |
0 to 80°C |
Accuracy
rating
(for 2-wire transmission) |
±0.3°C |
±0.5°C |
±0.3°C |
| Output
signal |
4 to 20mADC,
2-wire transmission (against measuring range) for
HN-C A
Pt100, 3-wire system for HN-C B |
Load
resistance
(2-wire transmission) |
500
or lower (at 24VDC power supply) |
| Sensor
interchangeablility |
Plug-in
interchageable |
Plug-in
interchangeable (including cable) |
Plug-in
interchageable |
| Working
temperature range |
Meter |
0 to 50°C |
|
|
|
|
| Sensor |
0 to 50°C |
-40 to
80°C |
-40 to
180°C |
0 to 50°C |
0 to 80°C |
| Power
Voltage |
12 to
24VDC ± 1V |
|
| Connection |
Crump
type no-screw terminal connection |
Terminal
connection (M4 x 5) |
| Material |
Meter |
Resin |
Die-cast
aluminum |
| Protective
tube |
---- |
Resin |
SUS |
| Mounting |
Screw
fixing (M4 x 2) or DIN rail mounting |
Screw
(M4 x 2) |
Flange
(JIS 5K 25A) |
| Weight |
About
160g |
About
220g |
About
240g |
About
1.6kg |
| Accessory |
Fixtures
for wall-mounting |
---- |
---- |
| Others |
---- |
Cable
length: 1m, 2m, 3m (to be specified) |
---- |
---- |