IM Series Infrared Multi Analyzer
|
|
|
|
| The IM series is an on-line multi IR wavelength analyzer utilizing the infrared absorption technology for measuring product constituent and/or thickness. Signal processing capabilities are built into the Compact All-In-One detector unit for easy installation and operation. A maximum of 99 calibration curves can be stored into the detector memory for numerous measurement applications. The detector can be used by itself or connected to a PC/plant control system, as both analog and digital outputs are provided. |
|
|
Features
- Up to 10 wavelengths, capable of measuring 4 constituents such as; moisture, film-thickness, organism, and coating-thickness in real time simultaneously.
- Connectivity to multiple interfaces, RS485 (MODBUS), Ethernet (LAN)
- High-speed & High-repeatability (28ms)
- Multi-calculation function
- Self-diagnostic function, easy maintenance.
- Conforms to CE standards and IP-65
|
| Configuration
|
 |
|
Models
|
Name
|
Model
|
| Moisture (Mirror type) |
General moisture |
IRMA1100
|
| High moisture |
IRMA1200 |
| Micro moisture |
IRMA1300 |
| Multi-component(NIR) |
IRMA51  |
Multi-component
(thin-film,Infrared) |
IRMA52  |
| Thickness,coating(Mirror type) |
Multi-component |
IRMA7100 |
Multi-component (thin-film,Infrared) |
IRMA7200 |
| Moisture(Fiber type) |
General moisture |
IRMA2100 |
| High moisture |
IRMA2200 |
| Thickness,coating(Fiber type) |
Multi-component |
IRMA61  |
| Thickness,coating |
IRMA8100 |
IRGMEG2
General Specifications
| Measuring
system |
Infrared absorption type |
| Measuring wavelength |
Up to 10 wavelengths |
| Measuring component |
Up to 4 constituents |
| Measuring distance |
200 to 400mm
(IRMA1300: 160 TO 300mm) |
| Measuring diameter |
50mm /300mm
(IRMA1300: 30 /200mm) |
| Analog output |
4 to 20mADC,±0.2E of full scale
(Load resistance: less than 500 ) |
| Communications |
RS-485 MODBUS |
| Computing |
2 or 3-color ratio calculation
Multiple regression calculation |
| No. of calibration curve |
Up to 99 curves |
| Working temperature |
0 to 50°C (Use dry air cooling if higher than 45°C. Outlet air temperature must be lower than 30°C.) |
| Power supply |
24V DC supplied from IR-WEP (IR-WEP power supply: 100-240VAC)
|
| Power consumption |
Approx. 30VA |
| Weight |
Approx. 4.3kg |
| CE-standards |
EMC directives EN61326+A |
| Input signal |
RS485, Up to 9 detectors connectable |
| Analog output |
4 to 20mADC, 2 output* (Load resistance: less than 500 )
* When multiple detector operation, outputs for detector No. 1 & 2.
|
| Communications |
RS-232C,
RS-485 or RS-422A (to be specified) |
| Alarm function |
Outputs contact signal (HCL) beyond setting-range |
| Power supply |
100 to 240V AC 50/60Hz |
| Power consumption |
Max. 15VA |
| Working ambient |
0 to 50EC |
| Weight |
Approx. 0.6kg |
- CE Standards specifications
| Analog
output
|
4
to 20mADC1 output (Load resistance: less than 500 ) |
| Power supply |
24VDC (within ±10%) |
| Power
consumption |
About
10VA |
*PDF data sheet is available at