IR-BZ Series Compact Infrared Thermometers

Data_Sheet
IR-BZ has separated detector and main unit to make the detector smaller and can be used at high temperature condition.
Main unit has digial temperature displays and parameter setting function.
Enables long stable measurement at affordable price.

Features

  • High accuracy and stable measurement even the environment temperature changes.
  • High speed response time 15ms, corresponds to production line requiring quick tracking.
  • Wide range temperature range from low to high temperature (0 to 1000°C)

Models

Models Detector cable length
IR-BZPHGE1 1.5m
IR-BZPHGE3 3m
IR-BZPHGE8 8m
IR-BZPHGEF 15m

Specifications

Measuring range 0 to 1000°C
Element Thermopile
Measuring wavelength 8 to 14µm
Accturacy rating Accuracy rating※1
Below 20°C: ±2°C
100°C ±:1°C
100°C or above: ±:1% of measuring
Response time 15ms
Emissivity 1.99 to 0.10
Analog output Output1: Measured temp. value
(select below by main unit)
Current output 0 to 20mA DC/4 to 20mADC
T/C output J/K/R/S
Output2:Detector temp. 0 to 5 V/-20 to 180°C
Working temperature Dctector:-20 to 100°C
Main unit:-10 to 65°C
Power 8 to 36 V DC
Detector cable Length 1.5m/3m/8m/15m(wire part)※2
OD:Φ:3.3mm
Covering:Fluorine resin
CE EMC directive…EN61326-1 Class A
(except IR-BZPHGE8, IR-BZPHGEF)
Conformity requirements
…Use of power supply for IR-BZ exclusive use and the connecting cable up to 30m(indoor use).
※1 Based on refernce operation condition 23℃ ±5℃,ε ≒1.0, factory default inspection result.
※2 Pliase specify the detector cable length. Detector cable cannot be removed.

Page Top